Basic Info.
Model NO. LRS-150-15
Output Power 101 - 200W
Connection Mode Series Switching Power Supply
Starting Mode Self-excited Switching Power Supply
Voltage Regulating Mode Frequency Modulation Type
Power Supplying System Terminal Power Distribution Equipment
Energy Transmission One-way Transmission
Modulation System PWM
Certification CE
Brand Leyu
Color Sliver
Rated Power 150W
OEM Accept
MOQ 1 PC
Application LED Lighting, Electrical Equipment
Protections Short Circuit / Overload / Over Voltage
Features Universal AC Input/ Full Range
Temp. Coefficient ±0.03%/℃ (0 ~ 50℃)
Storage Temp., Humidity -40 ~ +85℃, 10 ~ 95% Rh
Working Humidity 20 ~ 90% Rh Non-Condensing
Working Temp. -30 ~ +70℃ (Refer to Derating Curve)
Over Voltage 18.75~21.75V
Over Load 110 ~ 140% Rated Output Power
AC Current 2.8A/115VAC 1.6A/230VAC
Inrush Current Cold Start 60A/230VAC
Transport Package Cartoon
Specification 159*97*30mm(L*W*H)
Trademark Okey brand
Origin Zhejiang China
HS Code 8504401990
Production Capacity 5000PCS/Month
Packaging & Delivery
Package Size17.00cm * 11.00cm * 5.00cm Package Gross Weight0.800kg Lead Time 30 days (1 - 10 Pieces)
To be negotiated ( > 10 Pieces)
Product Description













CE approved 15V 10A 150W LRS-150-15 dc transformer power supply Good quality

Product Description

SPECIFICATION
OUTPUT
Model LRS-150-12 LRS-150-15 LRS-150-24 LRS-150-36 LRS-150-48
DC Voltage 12V 15V 24V 36V 48V
Rated Current 12.5A 10A 6.5A 4.3A 3.3A
Current Range 0~12.5A 0~10A 0~6.5A 0~4.3A 0~3.3A
Rated Power 150W 150W 156W 154.8W 158.4W
Ripple & Noise 150mVp-p 150mVp-p 200mVp-p 200mVp-p 200mVp-p
Voltage Adj. Range 10.2~ 13.8V 13.5~18V 21.6~28.8V 32.4~39.6V 43.2~52.8V
Voltage Tolerance ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
Line Regulation ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
Load Regulation ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
Setup, Rise Time 500ms, 30ms/230VAC 500ms, 30ms/115VAC at full load
Hold Up Time 40ms/230VAC 35ms/115VAC at full load
Voltage Range 85 ~ 132VAC / 170 ~264VAC 240 ~ 370VDC(switch on 230VAC)
Frequency Range 47 ~ 63Hz
Efficiency 87.5% 88.5% 89% 89% 90%
AC Current 2.8A/115VAC 1.6A/230VAC
Inrush Current Cold start 60A/230VAC
Leakage Current <0.75mA / 240VAC
Over Load 110 ~ 140% rated output power
Protection type: Hiccup mode, recovers automatically after fault condition is removed
Over Voltage 13.8 ~ 16.2V 18.75~21.75V 28.8 ~ 33.6V 41.4~48.6V 55.2~ 64.8V
Protection type: shut down o/p voltage, re-power on to recover
Working Temp. -30 ~ +70ºC (Refer to "derating curve")
Working Humidity 20 ~ 90% RH non-condensing
Storage Temp., Humidity -40 ~ +85ºC, 10 ~ 95% RH
Temp. Coefficient ±0.03%/ºC (0 ~ 50ºC)
Vibration 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
Safety Standards UL60950-1, TUV EN60950-1, EN60335-1/-2-16, CCC GB4943 approved
Withstand Voltage I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC
Isolation Resistance I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25ºC / 70% RH
EMC Emission Compliance to EN55022(CISPR22), GB9254 CLASS B, EN55014 EN61000-3-2,-3 class A, EN61000-3-3
EMC Immunity Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2(EN50082-2), heavy industry level, criteria A
Dimension 159*97*30mm (L*W*H)
Weight 0.48Kg
Packing 30pcs/carton/15.4kg/0.75CUFT
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature.2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.3. Tolerance: includes set up tolerance, line regulation and load regulation.4. Line regulation is measured from low line to high line at rated load.5. Load regulation is measured from 0% to 100% rated load.6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.